The positive pole of battery of laser pointer will be shown

The positive pole of battery of laser pointer will be shown.
Straight pipe length after the measuring point at least 0.5 times the pipe diameter; conditions permit to avoid installation in the strong electromagnetic interference, strong radiation, and highly corrosive environments. LGA-4000 laser gas analyzer measurements on the distance of the laser beam propagation, the average concentration of 1.2 If you can not find a straight pipe to meet the above requirements, this requirement can be relaxed . In addition, in order to facilitate the installation and maintenance easier installation and maintenance of the installation location, if necessary, must set up the installation and maintenance platform. Welding the welding of the flange. LGA-4000 laser gas analysis instrument for transmitting and receiving unit are installed in the tested pipe (flue) two welded flanges. After the customer presses the button of laser pointer .
Transmitter and receiver modules are designed light-way adjustment of the body, allowing the two flange concentricity deviation, but shall comply with Figure 3.2 shows the requirements, namely to ensure that the angle between the two flange axis line is not greater than 4o errors. Two welding flanges should generally be welded to the diameter of the measured pipe (flue) on the relative horizontal position. Two welding flange concentricity error allowed diagram. Installation, adjust the transmitter and receiver unit. After welding is completed the welding flange, you can begin installation and adjustment of the LGA-4000 laser gas analyzer emission unit and receiver unit. This section describes the work include: installation of the instrument flange, install the transmitter and receiver, and adjust the instrument flange coaxial. laser pointer can be used by the customer as the practical use.
Transmitting and receiving unit has a standard optical window can withstand a pressure of 5 kg. The picture shows the launch end of the electronic unit structure laser analyzer unit and the main components of a transmitter unit and rack installation nut 3. Optical window 4. Adapter ring 5. Calibration and purge unit purge gas inlet range unit entrance. receiver unit and the rack. DC power cable 10. receiver cable 11. liquid crystal display 3. installation greatly system to focus the two laser oxygen used in the table taken off the intubation of the way to install a two ∮ 50 2 600 mm stainless steel tube with a flange length, the middle to open a slot length of 400 mm, measured only in the actual measurement of the oxygen content of 400 mm length.

没有评论:

发表评论